Lapp Solar cable XLS-R T 2X6 BK/RD
Shipped in 1-3 days
solar cable xls-r t bk/rd solar cables - Key product features:
1. solar cables xls-r t are halogen-free, double-insulated and cross-linked twin cables for permanent outdoor use. These cables are used in the construction of photovoltaic systems both for wiring the individual solar modules to each other and for wiring to the inverter
2. Construction data --- Conductor: Fine stranded tinned cu wire, according to iec 60228, class 5 --- Core insulation: temperature resistant and halogen-free co-polyolefin, radiation crosslinked Pair colors: black/red --- Outer sheath: flame retardant and halogen-free co-polymer, radiation crosslinked Outer sheath color: black
3. Special features of the cross-linked compound are, besides the extended temperature range, very good values regarding uv-, ozone-, and weathering resistance as well as abrasion resistance. They are used for cabling solar modules to each other, as well as for connecting the individual module rows and the inverter.
This article is sold by the metre. Each item corresponds to one metre. If you buy e.g. 10x this article, you will receive a coherent piece with 10m length.
Electrical properties
Rated voltage u0/u according to vde: ac 600/1000 v / dc 900/1500 v
Maximum permissible dc voltage: 1.8 kv dc (conductor/conductor, not grounded system)
Test voltage ac 6.5 kv dielectric strength tests according to en 50395
thermal properties
temperature range fixed: -40° c to +100° c max. conductor temperature
Short circuit temperature +200°c
installation temperature flexible: max. -25 °c
thematic life according to en 60216-2
Thermal pressure resistance according to en 60811-3-1
Humidity-heat test according to en 60068-2-78 at 85% humidity
Mechanical properties
Minimum bending radius occasionally moved: 15 x cable diameter
permanently installed: 5 x cable diameter
Dynamic penetration: according to requirement profile ak 411.2.3 appendix F
Tear propagation resistance: according to requirement profile ak 411.2.3 Annex G
Testing of insulation and sheath tear strength as well as elongation: according to en 60811
chemical properties
Ozone resistance: according to en 50396 part 8.1.3 method B
Weathering / Uv resistance according to hd 605/A1
Fire behavior flame retardant according to iec 60332-1-2
Halogen-free according to iec 60754-1
Acid and alkali resistance according to en 60811-2-1 (oxalic acid and caustic soda)
EC Directives
The cables conform to the EC directives 2006/95/ec (low voltage directive) and 2002/95/ec and 2011/65/ec (RoHS, restriction of the use of certain hazardous substances).
installation in the ground
In principle, solar cables can be laid underground in protective pipes suitable for underground installation if it is ensured that there is no permanent contact with water and that waterlogging is safely drained away. The installation of the cables and the correct design of the cable trench must comply with vDE 0100 part 520 or comparable standards.